Discover the ideal solution for cost-effective industrial DC power needs with Non-PFC, Ultra-Economical LRS series power supply units. These compact and efficient units are designed to meet your power requirements while minimizing energy consumption and ensuring top-notch safety.
Key Features
Ultra-compact, 1U low-profile design, perfect for space-constrained environments
Robust 300VAC input surge protection,, built to withstand voltage fluctuations, ensuring uninterrupted power delivery even in challenging conditions.
It offers protection against overloading of up to 150% of the rated output, employing a Hiccup mode that automatically restores normal operation once the fault condition is resolved.
Impressive no-load power consumption range of 0.2W to 0.75W, contributing to substantial energy savings over time.
Built to handle extreme conditions with ease. They are designed to operate flawlessly in high-vibration environments, offering 5G vibration resistance, and can handle temperatures from -30°C to 70°C
Devices are engineered to perform at altitudes of up to 5000 meters, ensuring reliability even in elevated locations.
LRSs come with complete safety certifications, including IEC/EN60335-1(PD3), IEC/EN61558-1, -2-16; IEC/EN/UL62368-1, and GB4943.
Model Selection
LRS-35 |
LRS-35-5 | LRS-35-12 | LRS-35-15 | LRS-35-24 | LRS-35-36 | LRS-35-48 |
|
DC Voltage (V) |
5 |
12 |
15 |
24 |
36 |
48 |
|
Rated Current (A) |
7 |
3 |
2.4 |
1.5 |
1 |
0.8 |
|
Rated Power (W) |
35 |
36 |
36 |
36 |
36 |
38.4 |
|
Input Voltage |
85-264VAC (50/60Hz) 120-373VDC |
|||||
LRS-50 |
LRS-50-3.3 | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 |
|
DC Voltage (V) |
3.3 |
12 |
15 |
24 |
36 |
48 |
48 |
|
Rated Current (A) |
10 |
10 |
4.2 |
3.4 |
2.2 |
1.45 |
1.1 |
|
Rated Power (W) |
33 |
50 |
50.4 |
51 |
52.8 |
52.2 |
52.8 |
|
Input Voltage |
85-264VAC (50/60Hz) 120-373VDC |
||||||
LRS-75 |
LRS-75-5 | LRS-75-12 | LRS-75-15 | LRS-75-24 | LRS-75-36 | LRS-75-48 | |
|
DC Voltage (V) |
5 |
12 |
15 |
24 |
36 |
48 |
|
|
Rated Current (A) |
14 |
6 |
5 |
3.2 |
2.1 |
1.6 |
|
|
Rated Power (W) |
70 |
72 |
75 |
76.8 |
75.6 |
76.8 |
|
|
Input Voltage |
85-264VAC (50/60Hz) 120-373VDC |
||||||
LRS-100 |
LRS-100-3.3 | LRS-100-5 | LRS-100-12 | LRS-100-15 | LRS-100-24 | LRS-100-36 | LRS-100-48 |
|
DC Voltage (V) |
3.3 |
5 |
12 |
15 |
24 |
36 |
48 |
|
Rated Current (A) |
20 |
18 |
8.5 |
7 |
4.5 |
2.8 |
2.3 |
|
Rated Power (W) |
66 |
90 |
102 |
105 |
108 |
100.8 |
110.4 |
|
Input Voltage |
85-264VAC (50/60Hz) 120-373VDC |
||||||
LRS-150 |
LRS-150-12 | LRS-150-15 | LRS-150-24 | LRS-150-36 | LRS-150-48 |
|
DC Voltage (V) |
12 |
15 |
24 |
36 |
48 |
|
Rated Current (A) |
12.5 |
10 |
6.5 |
4.3 |
3.3 |
|
Rated Power (W) |
150 |
150 |
156 |
154.8 |
158.4 |
|
Input Voltage |
85 – 132VAC or 170-264VAC,47-63Hz (by switch), 240 – 370VDC (switch to 230VAC) |
||||
LRS-200 |
LRS-200-3.3 | LRS-200-4.2 | LRS-200-5 | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 |
|
DC Voltage (V) |
3.3 |
4.2 |
5 |
12 |
15 |
24 |
36 |
48 |
|
Rated Current (A) |
40 |
40 |
40 |
17 |
14 |
8.8 |
5.9 |
4.4 |
|
Rated Power (W) |
132 |
168 |
200 |
204 |
210 |
211.2 |
212.4 |
211.2 |
|
Input Voltage |
90 – 132 / 180 – 264VAC 47-63Hz (by switch) 240 – 370VDC (switch to 230VAC) |
|||||||
LRS-350 |
LRS-350-3.3 | LRS-350-4.2 | LRS-350-5 | LRS-350-12 | LRS-350-15 | LRS-350-24 | LRS-350-36 | LRS-350-48 |
|
DC Voltage (V) |
3.3 |
4.2 |
5 |
12 |
15 |
24 |
36 |
48 |
|
Rated Current (A) |
60 |
60 |
60 |
29 |
23.2 |
14.6 |
9.7 |
7.3 |
|
Rated Power (W) |
198 |
252 |
300 |
348 |
348 |
340.4 |
349.2 |
350.4 |
|
Input Voltage |
90 – 132 / 180 – 264 VAC 47-63Hz (by switch) 240 – 370VDC (switch to 230VAC) |
|||||||