Discover Total Temperature Control with the State-of-the-Art Temperature Controller!
Are you ready to revolutionize the way you manage temperature? Look no further than the Shinko BCx2 series cutting-edge Temperature Controllers. Engineered to perfection, it brings you intuitive operation, and a host of features that ensure optimal performance in every scenario.
Sample program
Simplified Program Control
Complex temperature profiles? Not a problem anymore. Our Temperature Controller offers simplified program control, enabling you to create intricate 12-steps temperature schedules with ease. Achieve precise temperature variations over time, opening doors to a world of possibilities in your processes.
AT On Startup Function
Efficiency meets innovation with our AT (Auto Tuning) on startup function. Experience hands-free optimization as the controller automatically tunes itself upon startup. This means quicker setup times and enhanced accuracy, allowing you to focus on what truly matters.
This function can be used when usual AT cannot be performed normally due to temperature fluctuations. PID parameters can be calculated only when the temperature is rising.
Convenient Initial Setting Mode
BCX2 Temperature Controller takes user-friendliness to a whole new level. The convenient initial setting mode guides you through the setup process, making it a breeze to get started. Say goodbye to time-consuming configuration struggles and hello to effortless operation from the get-go.
In this mode, frequently used setting items are collected.
Control can be started by setting those items in this mode.
Converter Function
Need to switch between controller and transmitter? The converter function has you covered. Effortlessly switch between PID controller and signal transmitter to match your preferences or meet specific requirements without any hassle.
This applies to DC current output type, the controller can be used as a converter.
Input signal is converted to insulated 0/4 to 20 mA DC, and output at the converted value.
A Variety of Event Input/Output Functions
Connect and customize. The controller boasts a wide array of event input/output functions, allowing you to synchronize temperature control with external events. Whether it’s triggering processes based on temperature changes or interfacing with other equipment, our controller adapts to your needs.
A maximum of 2 points of Event input (optional), and 2 points of Event output (1 point is standard).
Selectable from various Input/Output choices: Alarm output, Heater burnout alarm output (optional), Loop break alarm output, Time signal output, Pattern end output, etc.
Simple Settings From a PC
Take advantage of modern convenience. BCx2 controller allows for simple settings adjustments from your computer. Connect via a user-friendly interface and configure your controller’s settings effortlessly.
By connecting the BCx2 to a PC using the tool cable (sold separately), and by using dedicated software, various settings can be carried out. Wiring of BCx2 is not necessary as power to the BCx2 is supplied by PC via USB.
Drip-Proof/Dust-Proof IP 66
Rugged environments are no challenge for our Temperature Controller. With an IP 66 rating (for the front panel), it’s both drip-proof and dust-proof, ensuring reliable performance even in demanding conditions.
Specification
RTD – Pt100, jPt100 (3 wire)
DC current – 0 – 20mA, 4 – 20mA
DC voltage – 0-1V, 0-5V, 1-5V, 0-10V
SSR drive – 12VDC +/-15% (BCx2S)
Current drive – 0/4 – 20mA DC (BCx2A)
125ms
Relay – 3A 250A (resistive load)
100-240VAC or 24VAC/DC
-50° to 55°C , 35-85% RH (non-condensing, no icing)
Front panel: IP66
Black flame-resistant resin
BCS2 ~ 110g, BCR2 ~ 160g, BCD2 ~!220g
Model Selections
E.G, BCS2R10-06 for 48x48mm, relay output, 24V AC/DC with serial communication option.
| Size | Control Output | Power Supply | Input | Option 1 | Option 2 | Specification |
| BCS2 | 48x48x60mm | |||||
| BCR2 | 48x96x60mm | |||||
| BCD2 | 96x96x60mm | |||||
| R | Relay Contact | |||||
| S | 12V for SSR | |||||
| A | mA current | |||||
| 0 | 100 – 240V AC | |||||
| 1 | 24V AC/DC | |||||
| 0- | Multi-range | |||||
| 0 | No option | |||||
| 1 | EV2 – event output | |||||
| 2 | DS – Heating/Cooling control output OUT (V) | |||||
| 3 | DA – Heating/Cooling control (mA) | |||||
| 4 | P24 – 24VDC voltage supply | |||||
| 5 | EV2+DR – Event ouput EV2 + Heating/Cooling control (Relay) | |||||
| 6 | EV2+DS – Event output + Heating/Cooling output (V) | |||||
| 7 | EV2+DA – Event ouput + Heating/Cooling control (mA) | |||||
| 0 | No Option | |||||
| 1 | C5W (20A) Event input (2 points) + Serial Comm +Heater burnout alarm | |||||
| 2 | C5W (100A) Event input (2 points) + Serial Comm +Heater burnout alarm | |||||
| 3 | EIW (20A) Event input (2 points) + heater burnout alarm (20A) | |||||
| 4 | EIW (20A) Event input (2 points) + heater burnout alarm (100A) | |||||
| 5 | EIT Event input (2 points) + External setting input + Transmission output | |||||
| 6 | C5 serial comm | |||||
| 7 | W (20A) heater burnout alarm (20A) | |||||
| 8 | W(100A) heater burnout alarm (100A) | |||||
| 9 | EI Event input (2 points) |
Dimensions (mm)
Terminal Pinout
BCS2 terminal arrangement




